In daily life, what must everyone pay attention to when […]
In daily life, what must everyone pay attention to when using cold-pressed terminals? The following is a detailed introduction of the common problems of cold-pressed terminal manufacturers on the use of cold-pressed terminals.
1. Everyone should fully grasp the cold-pressed terminals to be actually operated and understand their operation steps to ensure proper actual operation. For cold-pressed terminals that do not prevent operation errors, color codes or logos should be used to identify them, or whether they can match the appropriate model specifications before connecting, and ensure proper and accurate positioning during connection. Care should be taken to prevent the misplugging of the pin power socket, otherwise it will destroy the cold-pressed terminal and cause accidental electrical contact to ensure that the cold-pressed terminal is connected in time. In a unique site that is not easy to inspect, actual standards should be formulated in the corresponding safety operating procedures and can be inspected based on speculum.
2. When the cold-pressed terminal is terminated, the termination and inspection shall be carried out strictly in accordance with the corresponding termination specifications or regulations, and the termination shall be carried out according to the corresponding connection point number. The thickness of the larger cable sheath in the middle of the selected cable line should be consistent with the spacing between the contacts, and the cable core should be consistent with the wiring ends of the contacts. When the span between the contacts and the lane change are resolved.
3. Electric soldering irons with corresponding output power should be used according to the diameter of the bare wire when welding. The welding time of each contact is generally not more than 5S. It should be noted that it is not necessary to let the flux penetrate into the conductor and insulator to prevent the product from being grounded. The resistance is reduced.
4. When the cold-pressed terminals are in a decentralized situation, they should install maintenance caps or adopt other anti-fouling measures; if the cold-pressed terminals do not dissolve for a long time after being connected, they can be safe between the power plug and the power socket.
5. When cleaning cold-pressed terminals, you can choose linen cloth dipped in industrial ethanol, and then apply it after drying. It is not allowed to use organic solvents such as toluene, which may cause harm to the connector.
6. When connecting or disassembling cold-pressed terminals, the power plug and the center line of the power socket should be overlapped as much as possible, and the cable should be corrected to prevent the power plug from being damaged by the tangential force, and to prevent the connector from being damaged due to the slack of the cable.
7. It is strictly forbidden to plug in the cold-pressed terminal before it is connected incorrectly or completely locked.
8. In places such as the fixing of cold-pressed terminals and the clamping of the whole vehicle wiring harness, anti-loosening equipment (anti-loosing screws, anti-loosing rings, fuse wires, etc.) must be used when external threaded connections are used.
9. When inspecting and inspecting cold-pressed terminals, it must be carried out in accordance with the relevant limits of the product and the provisions of the operating instructions. Inspect and inspect the electrical connectors used, be sure to lower the standards in the relevant limits of the product and the operating instructions. The cold-pressed terminals of the work clothes used must be completely undamaged. The probes with the characteristics of the standard must meet the limit requirements, otherwise the cold-pressed terminals. The socket is very easy to destroy.